icon's
legend:
|

more information |

application samples |

specifications |

presentations |
|
| Name |
 |
Brief description of instruments |
| Atomic Absorption Spectrometry |
 |
RA-915+ Mercury Analyzer
 |



|
RA-915+ Mercury Analyzer is a portable multifunctional
atomic absorption spectrometer with Zeeman background correction,
which eliminates the effect of interfering impurities. It is the
only high sensitivity and selectivity instrument that does not
require gold amalgam pre-concentration and subsequent regeneration
steps. This enables the user to conduct real time monitoring and
detection of a mercury vapor. Being combined with an RP-91 Cold
Vapor accessory for water and RP-91C pyrolysis attachment for
solid sample testing, the instrument is designed to determine
mercury content in ambient air, water, soil, natural and stack
gases, dental and medical testing and diagnostics, analysis of
food and marine life, etc., the mercury detection limits being
as low as 2 ng/m3 in air and 0.5 ng/l in water.
|
RA-915AM Air Mercury Monitor
 |

|
Background mercury monitoring of ambient air, technological control.
The RA-915AM monitor is designed for the continuous measurement of the mass
concentration of elemental mercury in ambient and indoor air, and technological
gases.
|
s
RA-915+ Mercury Analyzer with new pyrolyzer PYRO-915+
 |


 |
RA-915+ Mercury Analyzer with
new pyrolyzer PYRO-915+
(with large optical length of analytical cell (40 cm) and heated
windows of the analytical cell)is developed for unique direct
mercury determination (no pretreatment procedures required) in
complex organic samples at the level of few mg/kg.
|
RA-915 CEM
 |

|
Mercury continuous emission monitor is an industrial system for direct total mercury determination in stack gas with dry converter. Designed for outdoor installation on the stack, no heated lines needed.
|
MGA-915
 |


|
MGA-915 Atomic Absorption Spectrophotometer with electrothermal
sample atomization and enhanced Zeeman background correction features
a compact benchtop design, incorporating a fast 62.5-mm focal
length monochromator with a 1200-l/mm grating covering the 195-600-nm
spectral range, automatically controlled Massman graphite furnace,
and automatically interchangeable 6 hollow-cathode lamps or EDLs
on a rotated turret. It enables an analysis of more than 60 elements,
primarily heavy and toxic metals, to be carried out with very
low detection limits in such complex organic samples as milk,
juices, wines, or blood without preliminary sample digestion in
a totally automated computer-aided operation mode, including automated
adjustment for the given element. The spectrophotometer is equipped
with a 100-position autosampler. |
 |
| IR
Spectrometry |
 |
InfraLUM® FT-02
 |



|
InfraLUM® FT-02 FTIR Spectrometer contains,
as a basic unit, a state-of-the-art robust vibration- and misalignment-proof
Double-Cat-Eye interferometer of a proprietary design. The InfraLum®-02
covers the spectral range of 350-7500 cm-1 and provides
the photometric accuracy of 0.1%. The instrument is designed for
identification of unknown substances, quantitative analysis of
solutions and mixes, detection of impurities in atmospheric air
and gases, and other similar analyses. The large sample compartment
can accommodate all conventional and non-standard large cells
and accessories. The use of the dedicated user-friendly SpectraLum
control, data acquisition and processing software package, and
calibration and reference databases allows even an unskilled operator
to operate the instrument. |
InfraLUM® FT-10
 |



|
InfraLUM® FT-10 FT-NIR Analyzer is a multipurpose
near-IR (8500-14 500 cm-1) FT spectrometer, which is
designed for laboratory analysis of basic components of food products,
grains, and feed mixes, such as proteins, fats, moisture, sugar,
cellulose, starch, fibers, salt, etc., Determination of such biological
properties of a sample as the sprouting ability of seeds, caloric
content of food products, grain size, and others can be also achieved
using this machine. The instrument employs the NIR-transmission
technique, accommodates most of chemometrics prediction algorithms,
and allows for high flexibility of analysis methods. The analyzer
is controlled by a dedicated SpectraLUM/Pro® software,
which enables to carry out routine analyses in a very simple dialogue
mode, so that even an unskilled operator can operate the instrument.
|
InfraLUM® FT-20
 |

|
Fast non-destructive analysis of the sample composition and quality based on the FT-NIR diffuse reflectance spectrum registered with a bi-directional optical fiber probe. Applications: powders, fibers, films, suspensions, pastes, various finished products (in transparent packages as well). Process quality control in agriculture, food, cosmetic, polymer, pharmaceutical, paper and textile industries.
|
InfraLUM Whole Grain
 |

|
InfraLUM WholeGrain FT-NIR Analyzer is a near-IR FT spectrometer designed for laboratory analysis of basic properties/constituents of grain, such as protein, fats, moisture, sugar, cellulose, starch, fibres, etc. The instrument employs the NIR-transmission technique, accommodates most of chemometrics prediction algorithms, and allows for high flexibility of analysis methods. The analyzer provides very simple user interface via dedicated SpectraLUM/Pro software and touchscreen, which enables to carry out routine analyses in a dialogue mode, so that an operator can operate the instrument without any special training. The most precise FT spectrometry together with potion wise sampling ensures most accurate results that can be obtained by NIR spectrometry.
|
 |
| Capillary
electrophoresis |
 |
CAPEL®-series
 |


|
CAPEL-series Capillary Electrophoresis Systems. Capel-105M/105
and -103 are high-performance CE instruments equipped with light
sources and photometric detectors. Capel-105M and Capel-105M are
equipped with a UV monochromator, covering the 190-380-nm spectral
range, while model Capel-103 operates at a 254-nm wavelength.
Capel-103 has a manually controlled sampler with 4 inlet and 2
outlet positions, and Capel-105M and Capel-105 have autosampler
with 10 inlet and 10 outlet positions. The samples, rinsing and
buffer solutions are injected automatically by pressure or electrokinetically
according to a preset program. All the instruments are equipped
with capillary cassettes with effective liquid-cooled capillaries
of 30-100-cm in length and internal diameter of 25-100 µm, reversible
polarity ±25 kV voltage supply units. The dedicated software package
supports data acquisition and processing, data exchanges with
worksheets, databases and word processors. The systems are utilised
with software package from a PC that makes the analysis fully
automated.
|
 |
| Luminescent
and absorption photometric analysis |
 |
Fluorat®-02-series
 |


 |
Fluorat®-02-series Analyzers employ the
modular principle to diversify the highly sensitive and selective
luminescent analysis technique. The base unit, Fluorat®-02,
is a filter-based fluorometer, photometer, and chemoluminometer.
All these modes of operation are implemented in the same optoelectronic
scheme. In addition, the Fluorat®-02-2M
version is a time-resolving fluorometer, which can be used as
a fluorometric detector in any HPLC system. The analyzers are
equipped with high-pressure xenon arc lamps, with a high-intensity
light in the 200-650-nm spectral range, and are furnished with
appropriate sets of light filters and measuring cells. Fluorat®-02-02/3M
analyzers operate in a user-friendly menu mode to analyze common
contaminants, such as petroleum hydrocarbons, phenols, surfactants,
formaldehyde, nitrites, nitrates, sulfides, fluorides, and a number
of elements. The software package allows for saving calibration
tables and background value for 16 different components in the
built-in memory, and for printing out the results of analysis.
These analyzers can also operate with a fiber optic cable to measure
luminescence or reflected light from the surface of an outside
sample, such as paper, cathodoluminophors, etc. The small (300x300x90
mm) and light-weight (8 kg) analyzers are energized from an ac
mains or from a 12-V battery, which allows their use in mobile
laboratories
|
CRYO-1 and -2
 |


|
CRYO-1 and -2 Cryogenic Systems are designed for cryospectroluminescent
analyses of benz(a)pyrene in various objects and of lead in samples
of potable, natural and waste water, and in food products (in
addition, Bi, Te, and Se can also be detected). The system constains
a Fluorat®-02-2M analyzer and a cryogenic unit
(plus an LM-3 monochromator in Cryo-1), which are connected via
fiber optic bundles. The cryogenic unit, where a substance under
study is cooled to 77K using liquid nitrogen, consists of a rack,
Dewar vessel, and a device for the uniform feed of samples being
measured.
|
Fluorat®-02-Panorama Spectrofluorometer
 |


 |
Fluorat®-02-Panorama Spectrofluorometer
incorporates two monochromators in the luminescence excitation
and detection paths, which are arranged in a compact two-level
configuration, a xenon flashlamp as a light source, and a PMT
as a detector of luminescence signals. The monochromators employ
900-l/mm concave diffraction gratings with a 100-mm radius of
curvature, covering the 210-730-nm spectral range. The wavelengths
are set either from a built-in keypad or using a computer control
program. The instrument is designed for analysis of luminescence
spectra of liquid and solid samples, chromatographic analysis
of several components during a single eluation, and is capable
of scanning synchronous or two-dimensional spectra in both excitation
and luminescence detection paths.
|
 |
| Laser particle analyzer |
 |
Laser Particle Analyzer - LaSca-1C
 |

|
LaSca-1C is a high-precision instrument for analysis of kinetic processes and measuring size distributions of fine particles and cells.
|
 |
| High
Performance Liquid Chromatography (HPLC) |
 |
HPLC system
 |


|
Semi-microcolumn HPLC: High-pressure syringe pump, fluorometric/spectrofluorometric/photometric
detectors, premium quality columns.
Flexible modular system configuration
allows building systems to meet the needs for the majority of
the HPLC application. Simultaneous use of two detectors and compatibility
with all types of HPLC-detectors makes analysis even more informative.
Thermostating columns are
available.
|
Fluorat®-02-Panorama detector
 |


|
Specrtofluorometric FLUORAT®-02-PANORAMA analyzer
can be used to carry out very complicated analyses, such as polyaromatic
hydrocarbons. This instrument enables program-controlled adjustment
of both monochromators as a function of the eluation time. In
this analytical mode, several compounds, for example, 15 specified
polyaromatic hydrocarbons, can be detected with a very high sensitivity.
|
 |
| Syringe pump |
 |
Python-2
 |

|
Python-2 ia a high-pressure syringe pump (used as part of isocratic liquid chromatographs or as a precise dosing device). Applications: clinical and forensic analyses, pharmacology, sanitary and ecological inspection. Can be used as an auxiliary pump for a post-column reactor and as high-precision batcher.
|
| Automatic
Analyzers |
 |
Fluorat® A-series
 |


 |
Fluorat®A-series Automatic Flow Extraction
Analyzers are intended for stand-alone unattended continuous monitoring
of the content of petroleum hydrocarbons (0.005-5 mg/l), aluminum
(0.005-5 mg/l), active chlorine (0.03-3 mg/l), ozone (0.01-5 mg/l),
and surfactants (0.05-5 mg/l) in potable, natural, and waste water
or for assaying a series of samples using the fluorescence technique.
The instruments comprise a luminescence detector and a sample
preparation unit, which provides metered feed and switching of
the water and gas flows, and control of temperature, mixing, and
mass-exchange processes. In a stand-alone operating mode, the
selected reaction sequence can be assigned from a built-in keyboard
and allows wide-range altering the flow rates from 0.02 to 20
l/min. The instruments are equipped with RS-232 computer interfaces
for customized report output and remote computer-aided control.
Concentration measurement results, up to 1000, are stored in a
built-in memory and are displayed on a built-in LCD or printed
out. If the analysis result exceeds a permissible level, the alarm
mode is activated, and a final-control mechanism can be automatically
switched off by a command from the flow analyzer.
|
CKAT
 |


 |
CKAT-1 on-line turbidimeter monitor is intended for stand-alone
unattended continuous monitoring in ecological, technological
and sanitary purposes.
Principle of operation of this device is based on the effect of
light scattering by suspended particles and emulsions.
The instruments comprise a source of light, a water flowing cell
and a matrix of photodetectors and allow to detect a turbidity
in any natural and industrial water flows. The instruments are
equipped with RS-485 computer interfaces for customized report
output and remote computer-aided control. Concentration measurement
results, up to 1000, are stored in a built-in memory and are displayed
on a built-in LCD or printed out. If the analysis result exceeds
a permissible level, the alarm mode is activated, and a final-control
mechanism can be automatically switched off by a command from
the flow analyzer.
|
AKMC
 |


 |
AKMC-1 water hardness monitor is designed for stand-alone
unattended continuous monitoring. The principle of operation of
this instrument is based on potentiometric determination of the
total content of calcium and magnesium ions (water hardness) in
any natural or industrial water samples. The device may be used
for monitoring at water preparation facilities and for quality
control of feed water in power plants and in artesian-well water
softening.
AKMC-1 monitors consists of an electrochemical unit with
ion-selective electrodes and a standard unit with a hydraulic
unit. This design provides uninterrupted measurements of ion concentrations
in real time with automatic correction for variations of temperature
in the water flow.
The instruments are equipped with RS-485 computer interfaces for
customized report output and remote computer-aided control. Concentration
measurement results, up to 1000, are stored in a built-in memory
and are displayed on a built-in LCD or can be printed out. If
the analysis result exceeds certain level, the alarm mode is activated,
and a final-control mechanism can be automatically switched off
by a command from the flow analyzer.
|
 |
| Microwave
sample digestion |
 |
Minotavr®
 |


 |
Minotavr® Microwave Sample Digestor provides automated
full preparation of any samples for an elemental analysis by the
AAS, luminescence, or photometric technique. A sample of such
an organic substance as meat, fish, grains, bread, vegetables
and fruits, potable or waste water, soft drinks and alcoholic
beverages, tea and coffee, etc., is digested by a controlled 2450-MHz
and 40-400-W microwave field in a closed vessel under pressure
up to 8 atm, which ensures fast complete, and reproducible digestion,
preventing the sample from a loss of readily volatile elements
and reducing the consumption of reagents. Normally, a 2-g solid
or 50-ml liquid sample is completely decomposed in 15 to 30 min.
|
Minotavr®-2
 |

|
New universal microwave system for chemical process intensification MINOTAVR-2 Effective sample heating
Modular construction, possibility of simultaneous implementation of diverse or similar pre-treatment algorithms, temperature control, high digestion pressure in the container. Applications: microwave digestion, microwave extraction, hydrolysis of amino acids, synthesis.
|
 |
| Mass
Spectrometers |
 |
Mass spectrometr LUMAS-30
 |

|
Time-of-flight mass-spectrometry with pulsed discharge in hollow
cathode.
By dint of combination of gas-discharge ionization system with
time-of-flight ion detection technique there have been realized
high efficiency of sputtering of sample surface, high speed of
mass spectra registration over all range of detected masses and
high sensitivity for most elements.
|
 |
| Monochromators
|
 |
Monochromators
 |

 |
Monochromators line comprises MCD-2 double monochromators and
LM-3 monochromators, which are intended for the use with analytical
instruments operating in the UV-VIS (respectively, 280-710 nm
and 200-750 nm) spectral range. The MCD-2, which feature an extremely
high signal-to-noise light ratio of 3x106, are made
by a proprietary design concept based on two concave 1250-l/mm
diffraction gratings with a special groove profile and two deflecting
plane mirrors, which provides an F-number of 1:4 and a high resolution
of 0.33 nm throughout the working spectral range. The LM-3 have
one concave diffraction grating with a special groove profile,
the F-number being 1:3.3 and resolution 1.2-1.4 nm. In both
monochromators, slits are formed in easily removable fiber optical
bundles from 200-µm diameter quartz-quartz filaments packed in
rows.
|
 |
|
|
|