CAPEL-series Capillary Electrophoresis Systems
|
|
|
High performance capillary electrophoresis
Based on the differential migration of componenys of aqueous samples
within a narrow quartz capillary under the influence of the applied
electric field. Separated solutes are quantitatively detected at
the capillary outlet by high sensitive optical system based on direct
or indirect UV absorbance.
- high separation efficiency
- low reagent consumption
- simple sample preparation
- compact benchtop design
- autosamplers (10 inlet and 10 outlet vials) in CAPEL-105 and
CAPEL-105M
- user-friendly software
- implementation of various methods (capillary zone electrophoresis,
micellar electrokinetic chromatography, capillary isoelectric
focusing, capillary gel electrophoresis, capillary isotachophoresis
New features of Capel-105M:
- full control of the instrument from the PC
- broadened range of pre-set temperatures for liquid cooling
- fully automated programmable system with different levels of
task complexity - from manual operation through simple analysis
to complex sequence of runs
- extended operation options such as spectra scanning and broader
injection pressure range
- ability to apply controlled pressure simultaneously with the
high voltage during analysis
- substantially modified capillary cassette to provide liquid
cooling, simplify capillary replacement and increase the sensitivity
| DESCRIPTION
|
|
- Automatic pressure or electrokinetic sample injection
- Built-in capillary rinsing system
- Convenient access to the vials and capillary
- Possibility of visual check of the position of the
vials and capillary rinsing
- Liquid cooling system in CAPEL103 and in CAPEL-105,
CAPEL-105M
- Built-in monochromator (190 - 380 nm) in CAPEL-105
and CAPEL-105M
|
|
Common features for all CAPEL instruments provide clear benefits
for their users:
|
Feature
|
Benefit
|
| Copmplete control of the instrument from a PC |
User friendliness
|
| Highly efficient capillary liquid cooling |
Extended range of applied buffers, increased efficiency in separation |
| Powerful software package "Elforun®" |
- Increased flexibility in performing analyses of various complexit
- Any kind of complex runs are possible including those with pre-programming of changes in analysis conditions
- Customized report, data export to other programs
|
| Extended instrumental options |
- Spectra scanning facilitates peak identification (only for CAPEL-105M)
- Broad range of controlled pressure injection permits analysis of viscous samples
|
| Substantially modified capillary cassette |
- Easy capillary change just in a few minutes
- Lower Detection Limit due to the optimized optical scheme
|
Spectrophotometric detector, placed on Capel-105M, enables an operator
not only to select the most appropriate wavelength within the UV
range (190 - 380 nm) but also to perform spectral scanning of separated
compounds, thus supporting in peak identification.
Capel®-series CE systems can be supplied with validated measurement procedures (in accordance with EPA, ASTM and other standards).
Environmental analysis
- Soils (mobile forms of Co, Cu, Ni, Zn)
- Drinking, natural and waste water (Br -, I - and other inorganic and organic ions)
Quality control of foodstuffs and beverages
- Mineral and bottled water (inorganic cations and anions)
- Beverages and juices (inorganic cations and anions, sweeteners, antioxidants, vitamins, carbohydrates)
- Wines, brandies and vodkas (inorganic cations and anions, aromatic aldehydes, phenolcarbonyc acids, amino acids)
- Beer (inorganic cations and anions, hop and beer bitter acids (humulones and isohumulones, amino acids, vitamins)
- Tea, coffee (caffeine, catechin)
- Foodstuff (amino acids, synthetic dyes , organic acids, amines, proteins)
Pharmacology
- Technological monitoring and patent medicines analysis
- Enantiomers separation
Biochemistry
- Determination of inorganic cations and anions, amino acids and proteins in biological fluids
- Pharmacokinetics studies
- Protein separation
Forensic studies
- Analysis of explosives and trace detection
- Drugs analysis
Chemical industry
- Technological monitoring
- Composition determination of raw material and intermediate products
| DESIGN
AND OPERATION FEATURES |
Detectors
CAPEL-103 with one wavelength UV-detector lets you detect at 254
nm. CAPEL-105M and CAPEL-105M is equipped with variable wavelength
UV-detector, wavelength range 190 - 380 nm.
Vials
Standard 1.5 ml, minimal sample volume 100 µl.
Injection modes
Controlled pressure profile injection with variable peak pressure,
programmable peak pressure range being 0 - 60 mbar
Programmable injection time
Electrophoresis power
Voltage range settable from 1 to 25 kV
(manually reversible polarity)
Current from 0 to 200 mA
System control
Membrane keyboard
4 string 20 characters and 30 string 16 characters LCDs in Capel-103
and Capel-105/105M, respectively
Data acquisition and processing system based on a standard PC and
Chrom&Spec® software with MSWindows® user interface.
Chrom&Spec® software features
Real time electrophoregram visualization
Electrophoregram data processing
Computation of electrophoresis system parameters
Customized report output (hard copy and file), data exchanges with
worksheets, databases and word processors
Extensive data processing algorithm customization
GLP and GALP compliance.
Data exchanges with worksheets, databases and word processors.
APPLICATION
NOTES (more info) >>
- capillary electrophoresis system CAPEL®
(103R, 103RT , 104, 104M, 105, or 105M model)
- spare capillary cassette
- software package (for 103R, 103RT , 104, and 105 models - Chrom@Spec, for 104M and 105M models - Elforun®)
- kits for analysis [on request] ; the CE-kits of any manufacturers are compatible with Capel®-series CE systems
| SPECIFICATIONS |
| |
CAPEL-103R |
CAPEL-103RT |
CAPEL-104Ò CAPEL-104M |
CAPEL-105 CAPEL-105M |
| Detector |
254 nm |
190 - 380 nm |
| Analysis |
Constant voltage 1 – 25 kV in 1-kV steps, manual polarity
switching,
current 0 – 200 µA |
| Injection |
By voltage or by pressure |
| Rinsing |
By pressure 1000 mbar |
| Capillary |
Length/Internal diameter: 35– 100 cm/75 µm (optional:
50 µm) |
| Capillary cooling |
Liquid
cooling |
Liquid cooling with thermostabilization, from -10 up to +30oC with respect to ambient temperature |
| Sampler |
Manual
operation |
Autosamplers for 10 inlet and 10 outlet vials |
| Controlled parameters |
Time of analysis Pressure Voltage |
Time of analysis Pressure Temperature Voltage |
Time of analysis Wavelength Pressure Temperature Voltage |
| Power requirements |
110/220 Vac, 50/60 Hz (optional: 85 – 264 Vac) |
| Power consumption |
80 W |
150 W |
200 W |
| Size |
420x330x360 mm |
420x350x360 mm |
500x500x500 mm |
| Weight |
16 kg |
25 kg
30 (105M) kg |
|
All LUMEX equipment is covered by a 12-months warranty
Upon request installation and commissioning of CAPEL CE systems
can be carried out on Customer's site by our service engineers.
Consultations and initial training of attendance personnel with
due account of Customer's specific needs are performed. Spare parts
are delivered and repair is made upon Customer's request (free within
the warranty period).
|