PRINCIPLE OF OPERATION
Is based on the effect of light scattering by suspended particles or emulsions.
Description
- Continuous on-line monitoring
- High measurement accuracy
- Unaffected by stained inorganic ions and organic dyes
- High measuring rate
- Multipoint calibration
- Programmable sample intake rate
- Microprocessor based control
- Digital data processing
- Nonvolatile memory
- Self-test diagnostics
- NEMA 4X wall enclosure
APPLICATIONS
Ecological and sanitary monitoring
Manufacturing waste water monitoring
Drain water monitoring at thermal and nuclear power plants
Monitoring reservoirs with potential sources of pollution by petroleum hydrocarbons
Drain water monitoring at ore mining and processing enterprises
Technological monitoring
Quality control of water in technological circuits of thermal and nuclear power plants
Monitoring of water-preparation facilitiesQuality control of feed water for heating mains
Monitoring the operation of crushed ore thickeners at ore mining and processing enterprises
Quality control of high-purity water in semiconductor production
Specifications
Size of particles
0.5 – 50 µm
Range of detectable content of suspended particulate matter (petroleum hydrocarbons)
1.0 – 50 mg/L
Light source
670 nm
Relative photometric accuracy per channel
< 1 %
Sample temperature range
+ 0.5 to + 50 ºÑ
Sample pressure range
0.1 to 1 atm
Measuring time
2 – 10 sec.
Operating temperature range
+ 5 to + 50 ºÑ
Operating relative air humidity at + 25 ºÑ
< 80 %
Operating atmospheric pressure
84 to 106.7 kPa
Status signal output
NORM, ALARM, and LIMIT
Outputs
RS485, RS232, isolated 4 – 20 mA dc
Power requirements
ac 187 – 242 V, 50 ± 1 Hz, dc 12 V
Power consumption
100 W
Size
400õ300õ150 mm
Weight
20 kg
EQUIPMENT AND OPTIONS CKAT-1 on-line turbidimeter
Kit of spare parts and accessories with a flow cell
Set of reagents for preparation of standard suspensions
Set of standard samples (solutions of petroleum hydrocarbons in hexane)
Hydroseal (for analysis of water under overpressure)
Flow switching device and valves (for several sampling points)
Detector device (on Customer’s request)
WARRANTY
CKAT-1 on-line turbidimeter is covered by 18-months warranty.
SERVICES
Analysis of a technological process and working out recommendations to choose proper
CKAT-1 on-line turbidimeter version.
Development of a scheme and design for installing the analyzer (on Customer’s request).
Our service engineers carry out installation and commissioning of CKAT-1 on-line turbidimeter at Customer's site.
Consultations and initial training are given to attending personnel with due account of customer's specific needs.
Spare parts are delivered and repair is made upon Customer’s request (free within the warranty period).